JTECH Medical Manufacturer’s Certification and Functional Capacity Evaluator (FCE) Certification Seminar

JCT-FCE-2-horizontal-2014JCT-FCE-2014

JTECH Certified Training Coming to California in February/March 2015!

This Seminar Is Important to You and Your Success!

Is your Clinic getting all it can from the software it uses? What skills do you need to improve your clinics’s competitiveness in the FCE Market? At this training, you will gain a deep understanding of the process of collecting objective data and the underlying concepts according to published references, and best practices for reproducibility and reliability of data, which will set you and your clinic apart from your competitors. Manufacturer’s Certified Training is performed in person with emphasis on hands-on practicum, addressing questions, and ensuring that participants leave the event with an expertise beyond that of an average user. The goal of the JTECH certification training program is to raise the level of performance of all evaluators. Don’t miss this rare group certification course and the chance to learn first-hand from our JTECH Certified Trainers!


Modules Included in day 1:

 

Modules Included in day 2:

  • Inclinometry Range of Motion (ROM)
  • Muscle Testing
  • Grip/Pinch
  • Goniometry ROM
  • Static Lifting, & Algometry
 
  • Functional Testing Software
  • Analyze Data Software
  • Report Writing

Dates

JTECH Certified Training Saturday: February 28, 2015

FCE Software Training: March 1, 2015

Talk to a Specialist

 
 

gsaadvantage no url

  • PRODUCT HIGHLIGHTS
  • Why Go Wireless?
  • ACCESSORIES
  • SPECIFICATIONS
  • Downloads

Tracker Version 5 Grip Software Features

  • Includes standard maximum grip test, 5-position grip test, and rapid exchange grip (REG) test protocols
  • Features JTECH's sustained grip test with automatic force curves and fatigue calculation
  • Introduces our new multi-max grip test that follows the grip testing protocol outlined in the American Medical Association (AMA) Guides
  • Allows you to perform 1-4 repetitions per side
  • Speeds up data collection by allowing you to alternate sides
  • Calculates side-to-side difference
  • Automatically compares results to Mathiowetz or AMA norms
  • Includes multimedia help showing patient and instrument positioning for all standard tests
  • Calculates coefficient of variation (CV) for evaluating consistency of effort
  • Allows you to exclude reps from statistical calculations
  • Displays serial test-to-test comparison graph at testing screen
  • Creates effective data, narrative and progress reports
  • Pleasant voice prompts walk you through tests

While completely wireless system may seem like a luxury to some clinicians, they provide significant advantages over cable-connected systems.

Grip Cable (9AK103) – The Grip Cable is used for attaching calibration weights to the grip.

Optional Accessories:
Grip Stand (9AC010) – The Grip Stand holds the grip securely in a vertical position for testing on a table or desk.

Tracker Freedom Grip Gauge
Number of Repetitions per Test: 1-4
Load Cell Capacity: 200 lb (90.72 kg, 889 N)
Units of Measure: lb, kg, N
Weight: 0.86 lb (0.39 kg)
Length: 8.2 in (20.8 cm)
Width: 1.45 in (3.7 cm)
Depth: 3.85 in (9.8cm)
Battery Type: Rechargeable NiMH
Battery Life: Approximately 5 hours of continual use

Audible cues: . . . . . . . . . . . . . . . . . . . . . . . . . .  Yes
Automatic coefficient of variation calculations (CV): Yes
Automatic bilateral deficit calculation:. . . . . . . . . . Yes
Threshold settings: . . . . . . . . . . . . . . . . . . . . . .  0.25, 0.5, 1, 2, 5, 10, 20, 50lb.
Units of measure (pounds default):  . . . . . . . . . . . lb, kg, N
Automatic fatigue calculation:. . . . . . . . . . . . . . .  Yes
Timed test for fatigue evaluation. . . . . . . . . . . . . . Yes
Allows for specific test re-testing: . . . . . . . . . . . . Yes
Report Printing options: . . . . . . . . . . . . . . .  . . . .Yes